Construction DB | Construction Site Handbook | Temperature Test
Construction Site Handbook
Share your expertise and experience with the Construction DB community. You are free to add or edit any of the articles in the Construction Knowledge Collaboration Project.
[English | 简体] Temperature Test
Since the cement in concrete mix is mostly calcareous material and will evolve heat during the hydration process when meets with water , thus the temperature of the green concrete must be under control to avoid it is too high , particularly in hot season . The temperature control could be by means of the combination of , or the followings : -
1. Cooling down the temperature of the newly arrived cement before use .
2. The coarse and fine aggregates to be stockpiled under shelter .
3. The batching process to be carried out in the morning .
4. Addition of ice cubes .
5. Addition of chilled water .
Before the placement of ready mixed concrete to the final position , it should be tested with a laboratory standard certified ( or calibrated ) mercury thermometer ( shielded with metal casing ) with an accuracy of at least 0.5 degree Celsius . The acceptance of temperature range is to be in compliance with the Specification for various work and / or grade of concrete . Bear in mind to provide a few calibrated thermometers on site as these instruments are quite easily being broken .