Dye Test

This test is used to find out the apparent path of water leakage at the tidal zone or from high level to low level. Place the dyed water in the water inlet and record the location and time of test. The site supervisor should inspect the surrounding area, which may be quite remote from the water inlet, to watch out for where will be the dyed water coming out and respectively record the location and time of finding.